NG20

Generator protection

Several functions, required for synchronous generators and not self-started synchronous motors are included.


FUNCTIONS


STANDARD PROTECTIVE & CONTROL ELEMENTS

  • Sequence of Fault Recorder (SFR)
  • Sequence of event Recorder (SER)
  • Phase overcurrent side H and side L - 50/51
  • Overfrequency - 81O
  • Underfrequency - 81U
  • Residual Overvoltage - 59N
  • VT Supervision - 74VT
  • Voltage-controlled / restraint overcurrent - 51V
  • Overvoltage - 59
  • CT Supervision - 74CT
  • Under Voltage - 27
  • Directional active underpower - 37P
  • Breaker Failure - BF
  • Loss of Field - 40
  • Maximum Residual Overcurrent - 50N/51N(1)
  • Thermal Image Motor/Generator - 49MG
  • Minimum Power Factor - 55
  • Trip Circuit Supervision - 74TCS
  • Negative sequence overcurrent Motor/Generator - 46MG
  • Locked Rotor - 51LR(48)/14

SW PACK OPTIONAL CONFIGURATION

  • Digital Fault Recorder (DFR)
HW PACK OPTIONAL CONFIGURATION
  • Thermal with Pt100 Probes - 26

COMMUNICATION FUNCTIONS

  • Modbus TCP-IP
  • One USB Type B local port for communication with ThyVisor setup software
  • Modbus protocol RTU RS485 / IEC 870-5-103 / DNP3

DOWNLOADS

Flyer NG20
NG20 Coding
NG20 Manual

RELATED PRODUCTS

XMR-D

XMR-D is a part of XMORE platform, the complete range of IEDs for Medium Voltage application including feeder, motor, generator, transformer and capacitor bank; it is the multifunction and comprehensive Motor and Generator protection relay, including Differential element. Thanks to Hardware and Software modularity XMR-D is flexible and scalable in term of application and performance.


...

XMR-P


XMR-P is a part of XMORE platform, the complete range of IEDs for Medium Voltage application including feeder, motor, generator, transformer and capacitor bank; it is the multifunction and comprehensive Feeder, Transformer, Motor and Generator protection which includes an accurate and complete measurement, including Energy and Power.

Thanks to Hardware and Software modularity XMR-P is flexible and scalable in term of application and performance as:

  • Feeder Protection (Standard SW configuration)
  • Feeder Protection with additional Power protection element (SW PAC Power)
  • Feeder Protection with additional Directional Overcurrent and Earth Fault element (SW PAC Directional) 
  • Generator and Motor Protection relay (SW PAC Motor)
The relay is compliant with CEI-016 requirements

...