XA60

XA60 general protection relay

The XA60 protection relay can be used on radial and/or meshed MV and LV networks, providing reliable protection for power lines and transformers. It offers protection on radial, ring, or parallel lines of any length in systems with isolated, solidly grounded, Petersen coil, and/or resistance grounded neutrals.

It also provides effective earth fault protection for generators connected directly in parallel to the same busbar. Undervoltage and overvoltage functions are integrated as voltage protection or control, ensuring optimal system operation. The relay can be supplied with phase current input circuits suitable for both conventional CT and VT systems or integrated ThySensor devices. Both versions are certified for use as general protection of users connected to the MV distribution network in accordance with Italian standard CEI 0-16, in applications where directional and non-directional overcurrent and directional earth fault protection functions are required.

Features of the XA60 general protection relay


The Thytronic XA60 protection relay has several functions designed to ensure the safety of power lines and transformers. These standard protection and control functions include thermal protection for lines and transformers, undervoltage monitoring, phase overcurrent, residual overcurrent, overvoltage, residual overvoltage, directional phase overcurrent, and directional earth fault overcurrent. The relay is also capable of handling breaker failure, as well as CT, VT, and trip circuit supervision.

In addition, the XA60 relay provides metering, oscillography, event and fault logging, as well as control functions. Communication is available through USB, Modbus RS485, Modbus TCP/IP, IEC 60870-5-103, DNP3, and IEC 61850 Ed. 2, making the device suitable for advanced protection and supervision applications.


FUNCTIONS


STANDARD PROTECTIVE & CONTROL ELEMENTS

  • Directional Phase Overcurrent - 67
  • Maximum Residual Overcurrent - 50N/51N(1)
  • Thermal with Pt100 Probes - 26
  • CT Supervision - 74CT
  • VT Supervision - 74VT
  • Trip Circuit Supervision - 74TCS
  • Under Voltage - 27
  • Second Harmonic Restraint
  • Overvoltage - 59
  • Sequence of Fault Recorder (SFR)
  • Sequence of event Recorder (SER)
  • Residual Overvoltage - 59N
  • CEI 0-16
  • Ground directional overcurrent - 67N
  • Thermal Image Transformer - 49LT
  • Breaker Failure - BF
  • Phase overcurrent side H and side L - 50/51

SW PACK OPTIONAL CONFIGURATION

  • Digital Fault Recorder (DFR)
  • Thermal with Pt100 Probes - 26

COMMUNICATION FUNCTIONS

  • Modbus TCP-IP
  • One USB Type B local port for communication with ThyVisor setup software
  • Modbus protocol RTU RS485 / IEC 870-5-103 / DNP3

DOWNLOADS

XA60 Flyer
XA60 Operating Manual

RELATED PRODUCTS

XA30

The XA30 protection relay is designed to ensure maximum safety and reliability for medium-voltage (MV) electrical networks. It is the ideal solution for industrial plants, power distribution systems, and applications requiring advanced protection for lines and transformers.
Key Applications
  • Long radial lines in systems with isolated neutral or grounded through Petersen coil and/or high-value resistance.
  • Protection on the LV side of parallel transformers, regardless of the neutral grounding system.
  • Earth fault protection for generators or generator-transformer busbars connected in parallel to the same busbar.
The XA30 relay provides general protection for MV distribution networks, supporting overcurrent protection and directional earth fault protection for critical infrastructures.

Main Features of XA30 Protection Relay

  • Graphic LCD display with single-line diagram integration
  • 6 digital inputs for enhanced flexibility
  • High-precision measurements with event recording (SER), fault recording (SFR), and disturbance recording (DFR)
  • Modular and expandable hardware for scalable solutions
  • Advanced communication options:
  1. Front USB port
  2. Ethernet port with Modbus TCP/IP and IEC 61850 protocols
  3. Enhanced IEC 61850 for interoperability
  • Embedded programmable logic (IEC 61131)
  • ThyVisor PC software for easy configuration
  • Integrated Web Server (optional) for remote diagnostics
  • Integrated datalogger for operational monitoring
  • Modbus Master function (optional): concentrator for up to 4 devices via RS485

...

XMR-P

XMR-P is part of the XMORE platform, a complete range of IEDs for medium voltage applications that includes feeders, motors, generators, transformers, and capacitor banks. Thanks to its hardware and software modularity, XMR-P is flexible and scalable in terms of applications and performance.
 

Features of the XMR-P Protection Relay

The XMR-P multifunction relay is used in power grids with any neutral state (isolated, earthed with high or low value resistance, earthed with Petersen coil (compensated neutral) and any resistance, directly connected to earth) for the following typical applications:
  • Protection of radial lines, transformers
  • As a CEI 0-16 certified General Protection System ( SPG), with measurement inputs from inductive CT-VT or from ThySensor
  • Disconnection of self-producers from the electrical distribution network (LoM - Loss of Main); in particular, the version with inputs from ThySensor, is CEI 0-16 certified as SPG (general protection system) and integrated SPI (interface protection system).
With optional SW package, it is also possible to extend its application to:

► Loop lines or long radial lines, generators or transformers in parallel, thanks to directional phase (67) and ground (67N) protections

► For directional monitoring of active and/or reactive power

► As multifunctional motor or generator protection.

...